V Command - Define Variable
Use this command in forms that require unique
dataoneachlabel.Wheninitializingvariables:
·
They must be defined in order (e.g. V00 first,
V01 second...)
·
They must be the next entries after the
FS"FORMNAME" command
·
They must be located before any counter
variables.
To print the contents of the variable, the vari
-
able number is referenced in the “DATA” field
of the A (ASCII text) or B (Bar Code) com
-
mands.
The field justification parameter effects the way
the variable will be printed. When L of R are se-
lected, the variable value will be printed left or
right justified in an area with a widthdefined by
p
2
parameter.
The maximum amount of data stored as variable
data, includingcounter variables and datareference
overhead can not exceed 1500 bytes.
KDUSupport:Internallystoredvariabledatafields
are reset after cycling printer power or sending a re
-
set command or pressing the Cancel.
Example:
V00,15,N,"Enter Product Name:"¿