SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 11
The weight checked at each position on the scale, shown in Figure 4-4, represent halfway between the center
of the platter and corner. Use a stack configuration of weight
s if needed (i.e., (2) 5.00 lb weights, or (2) 2.500 kg
weights)
depending on the units of measure programmed.
Figure 4-4
Weight Positions on the Scale Platter
While performing a shift test, the indication of each positio
n is within the applicable tolerance and the range of
results obtained should not exceed twice the applicable tolerance.
Audit Tallies
Audit Tallies (calibration counter = C, legal parameter counter = P) used for scale verification can be shown on
the Scale Display, or the 7-segment display.
1. Press and hold the Scale Zero button for three seconds to access the calibration tallies (not within
Calibration mode).
a. C### and P### tallies blink on the Scale Display and/or scroll on the 7-segment display.
i. C### represents the number of times the scale reached Calibration Success on page 4-7. (Only
successful calibrations are counted.)
ii. The P### represents the number of times any sealable parameter, or legal parameter was
changed with or without reaching Calibration Success on page 4-7.
Scale Platter
Shaded Area
Represents the
Horizontal Window
IMPORTANT After verification, record/report audit trail information to the local Weights and Measure authority
where required by law.