3 - 8 MP6000 INTEGRATOR GUIDE
2. For added protection during shipment, the MP6000 platter is covered with a tight fitting layer of plastic as
shown in Figure 3-4. This plastic layer must be removed before placing the unit into service. (In the case of
a scale model, just before scale calibration; and, in case of a non-scale model, as the final step of
installation)
Figure 3-4
Platter Protector
3. Keep the packing (it is the approved shipping container, and should be used if the MP6000 needs to be
returned for servicing), or dispose of the packing in an environmentally sensitive manner.
Pre-Installation Notes
If a Scale Display is included, it is recommended to mount it in an appropriate location, preferably where
the old display was mounted. The cable should be routed through the checkstand.
If the unit includes a scale, scale calibration is required.
If the unit includes EAS Sensormatic:
it
s coils require installation
the large Sensormatic cable should be threaded from the controller box to the coils
The Sensormatic RS-232 cable should be connected to the unit.
If EAS Checkpoint is required, unravel the Checkpoint antenna and ensure a Checkpoint representative
connects the device to the controller.
If EAS Checkpoint with interlock is used, connect the interlock cable to the MP6000.
All accessories (hand-held scanner, CSS, etc.) require connections.
CAUTION Do not use a sharp object to remove the protector. Doing so can damage the platter.