Preventive and Corrective Maintenance
Printhead Cable
160
13291L-001 Rev. A S4M Maintenance Manual 10/27/05
10. Replace the strike plate cap.
11. See Figure 68. Check the gap on the ribbon/printhead open sensor and adjust as necessary.
Figure 68 • Ribbon/Printhead Open Sensor
12. Use a 0.060 in. (1.5 mm) feeler gauge and check the distance between the ribbon/head
open sensor assembly and the printhead housing. If the distance is incorrect loosen the
mounting screw for the ribbon/head open sensor and adjust for the proper distance. Once
this distance is achieved, tighten the mounting screw.
1
Printhead housing
2
Gap, 0.060 in. (1.5 mm) ± 0.015 in. (0.381 mm)
3
Ribbon/Printhead open sensor
4
Mounting screw
1
2
3
4