65
Operations
Control Panel LCD Display
10/27/05 S4M Maintenance Manual 13291L-001 Rev. A
RIBBON
Set Ribbon Use
Note • This parameter appears only for printers that have the
Thermal Transfer option installed.
Specifies the printing method: thermal transfer (using ribbon) or
direct thermal (no ribbon).
Selections:
• YES (thermal transfer mode, with ribbon)
• NO (direct thermal mode, no ribbon)
Default Value: YES
To modify this parameter:
• Press the up or down arrow to scroll through the selections.
ZPL OVERRIDE
(ZPL mode only)
Override Certain ZPL Commands
Prevents the printer from accepting the following ZPL commands:
•
^MM (media mode)
• ^MT (media type direct thermal or thermal transfer)
•
^MN (media non-continuous or continuous)
Selections:
• NO—allows the printer to accept the listed ZPL commands.
• YES—tells the printer to ignore the listed ZPL commands.
Default Value: NO
To modify this parameter:
• Press the up or down arrow to scroll through the selections.
EPL OVERRIDE
(EPL mode only)
Override Certain EPL Commands
Prevents the printer from accepting certain EPL commands.
Selections:
• DISABLED—allows the printer to accept the listed EPL commands.
• ENABLED—tells the printer to ignore the listed EPL commands.
Default Value: DISABLED
To modify this parameter:
• Press the up or down arrow to scroll through the selections.
Table 12 • Printer Parameters, Password Level 3 (Page 7 of 10)
Parameter Explanation