Page Setup
Parameters Used
10/22/2008 TTP2100 Technical Manual P1003640-001
Parameters Used
Parameter n35 – Document Mode
Set parameter n36 to 1 to enable black-mark check.
Parameters n37 and n38 – Page Length Minimum
Measure the distance from the center of one black-mark to the center of the next. The
resolution is 0.125 mm so multiply the distance by 8, then calculate the value to enter as n37
and n38.
Parameter n39 – Max Black-markLength
Measure the height of the black-mark or gap. The resolution is 0.125 mm so multiply the
black-mark length (in millimeters) by 8 and enter the value as n39.
Parameter n40 – Min Black-mark Length (Garbage Filter)
This parameter is actually a filter to filter-out garbage on the paper. If a spot or perforation is
smaller than this value, it will not be regarded as a black-mark. 1. About ⅓ of the black-mark
length is usually a suitable setting.
Example • If the page length is 100mm,
(100 x 8) / 256 = 3.125.
n37 is the integer value, that is 3, while n38 is the fraction, 0.125 x 256 = 32