6HFWLRQ 0DLQWHQDQFH
10. Refer to Figure 4-5. Reinstall the power supply board and main logic board in the
front cover, ensuring the rubber bezel slides into the slots in the front cover.
11. Refer to Figure 4-8. Route all harnesses to avoid pinching and screw posts.
12. Refer top Figure 4-7. Ensure the battery access door is in the slot of the front cover
with the flat side facing in.
13. Replace the cover and shoulder strap.
14. Reinstall the battery. Connect a battery charger if necessary.
15. Perform the procedure Calibrate Ribbon Sensor on page 2-18.
16. load the media, and perform an auto-calibration.