77259L Rev. 4 12/16/03 Z4M/Z6M Maintenance Manual Page 2-27
2SHUDWLRQV2YHUYLHZ 6HFWLRQ
Figure 2-16. FEED Key Self Test Label
3DXVHDQG&DQFHO.H\6HOI7HVW
Press and hold both PAUSE and CANCEL while turning the printer power On (l).
Release both keys anytime after the first front panel LED turns off.
The Pause and Cancel Key Self Test prints a series of 500 labels which can be used when
making print quality adjustments. The printed label will look like the PAUSE Key Self
Test label and will be sequentially numbered.
Figure 2-17 provides an example of PAUSE and CANCEL Self Test label.
Figure 2-17. PAUSE and CANCEL Key Self Test Label