^SO
Set Offset (for Real Time Clock)
Description: The ^SO command is used to set the secondary and the tertiary offset
from the primary Real Time Clock.
Format: ^SO
Parameters:
a = clock set
Accepted Values: 2 (secondary) or 3 (tertiary)
Default Value: value must be specified
b = months offset
Accepted Values: -32000 to 32000
Default Value: 0
c = days offset
Accepted Values: -32000 to 32000
Default Value: 0
d = years offset
Accepted Values: -32000 to 32000
Default Value: 0
e = hours offset
Accepted Values: -32000 to 32000
Default Value: 0
f = minutes offset
Accepted Values: -32000 to 32000
Default Value: 0
g = seconds offset
Accepted Values: -32000 to 32000
Default Value: 0
ZPL II Programming Guide Volume One: Command Reference for X.10