4 - 12 MP6000 BAR CODE PROGRAMMING GUIDE
Scale Display Configuration
Parameter # 986
Scan Enable Scale Display Configuration below to enable the pole display port. Scale Display Configuration
is disabled by default.
Options:
Enable Scale Display Configuration: When a pole display is installed and connected to the
MP6000/scale, the pole display shows weight, and/or additional alphanumeric information associated
with the state of the scale. If a pole display is not connected, and Enable Scale Display Configuration
is scanned, the 7-segment display scrolls the code U23 indicating that there is a remote Scale Display
communication error.
*Disable Scale Display Configuration: Scan this parameter when no Scale Display is installed. When a
Scale Display is installed and connected to the MP6000/scale, the Scale Display remains blank. The
Scale Display can be installed and programmed in any mode of operation.
Refer to the MP6000 Integrator Guide (p/n 72E-163525-xx) for detailed information about the audit trail, scale
calibration, and error/warning conditions.
Enable Scale Display Configuration