SYMBOLOGIES 11 - 233
Code 128 Emulation
Parameter # 123
Enable this parameter to transmit data from certain MicroPDF417 symbols as Code 128. AIM Code ID
Character (01h) on page 5-80 must be enabled for this parameter to work.
Enable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes:
]C1 if the first codeword is 903-905
]C2 if the first codeword is 908 or 909
]C0 if the first codeword is 910 or 911
Disable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes:
]L3 if the first codeword is 903-905
]L4 if the first codeword is 908 or 909
]L5 if the first codeword is 910 or 911
Enable or disable Code 128 Emulation.
Options:
Enable Code 128 Emulation
*Disable Code 128 Emulation.
Enable Code 128 Emulation
(01h)
NOTE Linked MicroPDF codewords 906, 907, 912, 914, and 915 are not supported. Use GS1 Composites
instead.