11 - 84 MP6000 BAR CODE PROGRAMMING GUIDE
ISBT Concatenation
Parameter # 577
Select an option for concatenating pairs of ISBT code types:
•
*Disable ISBT Concatenation - The MP6000 does not concatenate pairs of ISBT codes it
encounters.
•
Enable ISBT Concatenation - There must be two ISBT codes in order for the MP6000 to decode and
perform concatenation. The MP6000 does not decode single ISBT symbols.
•
Autodiscriminate ISBT Concatenation - The MP6000 decodes and concatenates pairs of ISBT codes
immediately. If only a single ISBT symbol is present, the MP6000 must decode the symbol the number of
times set via ISBT Concatenation Redundancy on page 11-89 before transmitting its data to confirm that
there is no additional ISBT symbol.
*Disable ISBT Concatenation
(00h)