RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-38 •
Installing the New Upper Housing
1. If you removed a Card Reader from the printer, re-install it in the new Keypad
and Housing. Arrange the Keypad and LCD ex circuits so they are between
the back of the Card reader assembly and the LCD assembly. Secure the Card
Reader with (4) screws.
2. If your printer has a Card Reader option, plug the two cables from the card
reader into the Legacy PCB on the retained radio assembly.
3. Install the radio assembly, or the Bracket Radios into the Keypad and Housing.
Secure it in place with (3) screws. If the Radio assembly has an external
antenna card, insert the antenna card into the upper housing.
Remove and retain Card
Reader Assembly and
attaching hardware.