• 2-71 • RMAN-RWS-001 rev. B • RW Series Repair Procedures
3. Secure the Media Assembly to the Printer Frame with (2) Screws.
4. Reinstall the Printer Frame to the Lower Housing. Refer to procedure
RK17479-007 for more details.
6. Plug the Gap Sensor Cable to the CPU Board Use the the table below for
reference. If you unplugged the Motor cable, plug it into J6 at this time.
CPU CONNECTIONS
CABLE CPU CONNECTOR
MOTOR CABLE J6
BAR SENSOR FLEX CABLE J2
GAP SENSOR FLEX CABLE J10
PRINTHEAD CABLE J5
7. Install the Upper Housing. Refer to the procedure for RK17479-008 and
RK17479-009 for more details. Ensure that the “D” Rings or optional hand strap
components are installed.
8. Install the battery.
9. Re-Calibrate the Sensors.
Thecalibrationprocedurecanonlybeperformedbycertiedpersonnelusing
special equipment and software.
Using the gray and white swatches, follow the on-screen instructions on
the unit test and set-up software to properly calibrate the sensors. It is
recommended that the complete unit test procedure be performed whenever a
sensor assembly has been replaced.
Screw, #4-40 x 1/4” Pan
Hd. Phillip Nylon (2)
p/n TH-SJ0803N