Zebra RW SERIES Dokumentacja Strona 77

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 114
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 76
• 2-77 • RMAN-RWS-001 rev. B • RW Series Repair Procedures
2. Install the (2) Springs, Printhead supplied with the repair kit to the Bar, Spring.
3. Re-assemble the Bar, Spring to the Printer Frame. Ensure that the Printhead
Springs are seated over the heads of the screws securing the tear bar to the
printhead
4 Plug in the Printhead, Bar Sensor and the Gap Sensor Cable to the CPU Board
per the table below. If you unplugged the Motor cable, plug it into J6 at this
time.
CPU CONNECTIONS
CABLE CPU CONNECTOR
MOTOR CABLE J6
BAR SENSOR FLEX CABLE J2
GAP SENSOR FLEX CABLE J10
PRINTHEAD CABLE J5
5. Re-secure the CPU Board. Refer to Procedure RK17949-014 for more details.
6. Install the Upper Housing Assembly. Refer to Procedure RK17949-008/-009 for
more details. Also ensure you have re-installed the D-Rings between the Upper
and Lower Housings.
7. Install the Battery Pack and media and perform a two-key reset to verify that
the Printhead has been properly installed.
8. Perform the Unit Test procedure. Perform a complete unit test to ensure that
the sensor calibrations are still correct.
Thetestprocedurecanonlybeperformedbycertiedpersonnelusingspecial
equipment and software.
Bar, Spring
Replacement Printhead
Springs (2)
p/n BA17932-1
(Included with RK17949-005)
Przeglądanie stron 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 113 114

Komentarze do niniejszej Instrukcji

Brak uwag